Interfaces for tool setting arms and probes for turning centres.
Tool setting interface options
| TSI 2 |
|
TSI 3 |
|
TSI 2-C |
|
TSI 3-C |
Use with HPRA, HPPA |
|
Use with HPMA, HPGA |
|
Use with HPRA, HPPA |
|
Use with HPMA |
| TSI 2 can be DIN rail mounted within the machine control cabinet. |
|
TSI 3 units are DIN rail-mounted and feature an 'Easy fit' location mechanism. |
|
As the TSI 2 but with Solid state relay (SSR) output for easier user configuration. |
|
As the TSI 3 but with Solid state relay (SSR) output for easier user configuration. | TSI 2 specification
| Specification |
|
| Principal application |
Hard-wired probing systems with HPRA and HPPA |
| Mounting |
DIN rail mounting |
| Outputs |
1. Probe status (no complement)
2. Position confirm signals (machine ready and arm ready) |
| Output signal format |
1. Unipolar active high probe status outputs (non configurable)
2. Unipolar active high confirm outputs for machine ready and arm ready positions (non configurable) |
| Other I/O |
Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs. |
| Power supply |
18 V - 30 V dc, Imax = 50 mA not including output loading.
Fuse protected at 250 mA (FF) |
| TTL compatibility |
Not compatible |
| Inputs |
1. Inhibit
2. Probe select inputs |
| Input signal format |
1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH |
| Probe vibration filter |
A trigger delay circuit (6.5 ms) can be activated by reversing the brown and white wire connections to the TSI 2 (PL2-1 and PL2-3) |
TSI 3 specification
| Specification |
|
| Principal application |
Hard-wired probing systems with HPMA and HPGA. |
| Mounting |
DIN rail mounting |
| Outputs |
1. Probe status (no complement)
2. Position confirm signals (machine ready and arm ready) |
| Output signal format |
1. Unipolar active high probe status outputs (non configurable)
2. Unipolar active high confirm outputs for machine ready and arm ready positions (non configurable) |
| Other I/O |
Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs. |
| Power supply |
Interface voltage supply (1, 13, 25) 18 V - 30 V dc, Imax = 100 mA not including output loading.
Motor voltage supply (10, 22, 11, 23) 24 V dc + 20% - 10%, Imax + 2.5 A for 4 s (worst case stall). Overcurrent and reverse connection protected.
Self-resettable |
| TTL compatibility |
Not compatible |
| Inputs |
1. Inhibit, Arm ready, Machine ready
2. Probe Select inputs2. Probe select inputs |
| Input signal format |
1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH |
| Probe vibration filter |
A trigger delay circuit (6.5ms) can be activated by reversing the brown and white wire connections to the TSI 3 (PL2-1 and PL2-3) |
TSI 2-C specification
| Specification |
|
| Principal application |
Hard-wired probing systems with HPRA and HPPA |
| Mounting |
DIN rail mounting |
| Outputs |
1. Probe status (N/O or N/C)
2. Position confirm signals (machine ready and arm ready) |
| Output signal format - voltage free SSR |
Probe status N/C or N/O, MRO and ARO N/O
Maximum current 40 mA
Maximum voltage 30 V
Outputs are protected by fuses (TE5) (f) 50mA |
| Other I/O |
Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs. |
| Power supply |
18 V - 30 V dc, Imax = 50 mA not including output loading.
Fuse protected at 250 mA (FF) |
| TTL compatibility |
Not compatible |
| Inputs |
1. Inhibit
2. Probe select inputs |
| Input signal format |
1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH |
| Probe vibration filter |
A trigger delay circuit (6.5 ms) can be activated by reversing the brown and white wire connections to the TSI 2 (PL2-1 and PL2-3) |
TSI 3-C specification
| Specification |
|
| Principal application |
Hard-wired probing systems with HPMA. |
| Mounting |
DIN rail mounting |
| Outputs |
1. Probe status (N/O or N/C)
2. Position confirm signals (machine ready and arm ready) |
| Output signal format - voltage free SSR |
Probe status N/C or N/O, MRO and ARO N/O
Maximum current 40 mA
Maximum voltage 30 V
Outputs are protected by fuses (TE5) (f) 50mA |
| Other I/O |
Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs. |
| Power supply |
Interface voltage supply (1, 13, 25) 18 V - 30 V dc, Imax = 100 mA not including output loading.
Motor voltage supply (10, 22, 11, 23) 24 V dc + 20% - 10%, Imax + 2.5 A for 4 s (worst case stall). Overcurrent and reverse connection protected.
Self-resettable |
| TTL compatibility |
Not compatible |
| Inputs |
1. Inhibit, Arm ready, Machine ready
2. Probe Select inputs2. Probe select inputs |
| Input signal format |
1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH |
| Probe vibration filter |
A trigger delay circuit (6.5ms) can be activated by reversing the brown and white wire connections to the TSI 3 (PL2-1 and PL2-3) | |